zurück



DLT | Continuous Beam | Update Information


Version 02/17


Reinforced concrete

for indirect supports the first design location for determination of reinforcement of joints is at the edge of support.

General

Reduction of loads from load transfer by PLT or GEO corrected.

Timber

For all National Annexes the vibration check can be done alternatively according to ÖNORM B 1995:2015.


Version 01/17


General

Output of GammaM for earthquakes in earthquakes combinations.

Timber

New softwood and hardwood implemented according to EN 338:2016.
Output information for factor kh in case of hardwood according to Eurocode 5.
Suggestion of timber type dependent burning rates.


Version 02/16


Load combination

Change of MLTB-Interpretation for northgerman plateau implemented.
Snow as exceptinal load will now superimposed with all loads.

Reinforced concrete

Combination for deflections in state II selectable

Eurocodes

DIN EN 1992:2015 and BS EN 1992:2015 implemented

Timber

Glulam according to EN 14080:2013 implemented for Germany and Italy.
The "old" Glulam timbers are marked with * (for example GL24c*).


Version 01/16


Timber

ÖNORM EN 1995:2015 implemented.
For Fire design accident effects are no more considered ( EN 1992-1-2 4.2.2(1).
Option accoring to EN1995 2.3.2.2 (2.10): Calculation with reduced E-Modulus for timber in combination with steel strengthened timber girder.

Steel / Aluminium

Combination for SLS deflections selectable.

Reinforced concrete

Output problems with horizontal shearforce connection eliminated.


Version 02/15


Addition

DLT starts with default design code, which is determined in the FCC project environment.

Reinforced concrete

Permitted crack width can be defined by the user.

Timber

Update for DIN EN 1995:2013 in combination with Eurocode EN 1995:2014.

Aluminium

For cross sections, which are described by cross section values, is it possible to put in fo for the choosen material. Proof for by cross section values described cross sections will be based at these fo.


Version 01/15A


Timber

If DLT10 is called by other timber-programs permitted wnet is set by DLT .
For DIN EN1995:2013 is shown on design-window wfin, if this deflection is authoritative.


Version 01/15


Addition

Load transfer to HO1+ is implemented.

Timber

Issues for calculation of kcr for t-beam cross-sections fixed.
Item can be saved with wnet,fin now.
Correction of load case combination with fire design: The leading action is not based on the kmod value from the design of normal temperature anymore.


Version 02/14D


Steel

EN 1993: Wind is considered with Psi1 = 0.2

Timber

Issues with FDD-Output in case of fire design fixed.


Version 02/14C


Timber

Issues with haunches in case of fire design fixed.
Gluelam with vertical laminations according to DIN EN 1995: The increased permitted strength is documented in the output now.


Version 02/14B


Timber

Issue with change from gluelam to solid wood eliminated. Kc90-Info is shown for DIN EN1995-1-1/NA:2013-08 too.


Version 02/14A


Reinforced concrete

Problem of output of bar schedule (multiple output) eliminated


Correction

For settlement of supports is now for calculation the consideration of shear deformation possible.


Version 02/14


Timber

Fire design according to EN 1995-1-2 implemented.
New dialogue for input for proof of oscilliations including support for input of stiffnesses.
design according DIN EN1995-1-1/NA:2013-08 is now possible (Attention : This code is oficially still not introduced !).
For design according DIN EN1995-1-1/NA:2013-08 for combinations with wind as shortest action kmod is calculated as arithmetic mean of short and very short.


Version 01/14A


Reinforced concrete

correction of support reinforcement at right cantilever : problems eliminated, which occured calculating support reinforcement at the right cantilever if there are no negative support moments.


Version 01/14


Timber

for proof according EN1995-1-1 the deflection wnet will now put out too .



Version 02/13A


Timber

Proof of oscillation was performed until now for all spans with the first cross section of the girder. Now it will performed with the first cross section of the actual span.
For ÖNorm EN 1995 perm wF within proof of oscillation will determined acc. 5.7.3 of NA Austria.

Reinforced concrete

EN1992: 2010 introduced
For symetric design acc. EN1992 the minimum excentricity is still only considered, if the internal normal force is a compressive force.


Version 02/13


General

If there are eartquakeloads or accidental loads, in the ouput is shown a message, which decribes how the program considers these loads.

Timber

problems with output of kcr eliminated.
For Output of deflections acc. EN5 under 2-axis loads for wq,fin in y-direction was put out wq,fin in z-direction.
This problem was eliminated.


Version 01/13B


Aluminium

For proof acc. EN 1999-1-1 is Psi0 for calculation of internal forces considered, if several actions are acitve.


Version 01/13A


Reinforced concrete

problem with calculation of minimum support moments under consideration of alternativ loadcases eliminated.
If supports are indirect, single loads near supports are no longer reduced for calculation of reinforcement of joints.

Timber

For proof acc. EN1995 for T-beam cross.sections of timber kcr will be considered.

Aluminium

Proof acc. DIN EN 1999-1-1 possible.


Version 01/13


Timber

For proof of oscillation the value for permitted acceleration can be defined by user now. For EN5 is ist possible to disable optionally the output of proof of acceleration if f1 > 8 Hz.

Steel

proof according EN 1993 6.2.1 (6.1) is performed now for cross-section class 4 too.

Reinforced concrete

Preset of option for design of shear of slabs with cross-section of beam put to "design as slab".


Version 02/12D


Reinforced concrete

EN2: Missing reduction of Vred for individual loads near supports

Timber

For EN5 were not valid materials selectable. This problem is eliminated now.


Version 02/12C


Reinforced concrete

action of creeping for calculation of deflection due state II modified.

Timber

For calculation of alpha and n40, in proof of oscillation, the stiffness of length is considered per m.

Steel

problems with haunches for proof of EN3 eliminated.


Version 02/12B


Timber

for calculation of glulam with vertical Lamina was kh considered twice.This problem was eliminated.


Version 02/12A


Timber

for girders of timber strenghtened with steel, which proofed according EN5 Germany respectively Austria, could it occure that the proof of steel-part according EN3 Germany respectively Austria did not deliver results. This problem was eliminated.


Version 02/12


Reinforced concrete

reduction of single loads near of supports

Timber

design window shows the exploitation of deflection of cantilevers only, if this option is selected for output.

General

acc. EN consequency classes are considered.


Version 01/12B


Timber

for girders of timber, which are strengthened with steel, and proofed for timber by EN5 Germany respectively Austria the steel-part will be proofed by EN3 Germany respectively Austria.


Version 01/12A


Reinforced concrete

shear design of slabs acc. DIN 1045:1988 was frequently aborted. This problem is elimninated now.

Timber

problems in design window for exploitation of deflections under EN5 eleminated.


Version 01/12


Steel

design acc. EN3 possible.

Reinforced concrete

for shear design of a reinforced slab with a cross section of a beam, may be optionally decided if you want a shear design for slab or for beam.
New dialogue for creep and shrinkage.


Version 02/11


Timber

proof of swinging acc. EN5 possible.
problems for proof of shear for strengthening cross-sections of timber eliminated.

Steel

For girders with cantilever is put out now an advice, that for the proof of torsional-flexural buckling for the cantilever is impediment of warping considered.


Version 01/11D


Reinforced concrete

problems of design of steel-concrete interface eliminated


Version 01/11C


Reinforced concrete

Problems with transfer to Glaser eliminated.

Timber

For with steel-profiles strengthened cross-sections of timber girders, the strengthened steel-profile will designed according DIN 18800, if the timber cross-section is designed according EN5.


Version 01/11B


Reinforced concrete

For As-line for bi-axial effect of actions, scale for output per corner adapted.

General

In english version loadtypes 11-16 of overspan loads translated.


Version 01/11A


If option "Inmediate calculation after loading a position" was not active, it could lead during the saving of position to an abortion of the program . This problem was solved.


Version 01/11


Reinforced concrete

for proof of shoulder shear for one-sided flanged beams is now the one-sided breadth of the flanged beam considered.

Timber

redistribution acc. DIN 1052:2008 optional possible.
support moments will be now optionally reduced.




Version 02/10C


Reinforced concrete

for shearforce design for two-axis actions the outputtable contained instead the authoritative reinforcement the reinforcement of the last calculated combination. This problem was eliminated.


Version 02/10B


Reinforced concrete

in head of table for support reiforcement as dimension of the support reiforcement were written mm2 instead of cm2. this problem was eliminated.


Version 02/10A


Timber

for EN5-ÖNorm-2010 appears now the adequate material window.


Version 02/10


Timber

problem with proof against buckling eliminated (alternating lengths of buckling were not considered until now).

Steel

calculation of BTII accelerated.

Reinforced concrete

haunches are correctly considered with d instead of h.
in the last column of output of deflections fII the maximum value is put out now.
EN2 Belgium, Netherlands and Czechia added.


Version 01/10D


Reinforced concrete

problems with shear design at haunches corrected.

Timber

fmk for combined gluelam will no longer increased.


Version 01/10C


for Ho7 Output steico-joist under DIN 1052:2008


Version 01/10B


designing a girder of timber acc. DIN 1052:2004 or 2008 could a change of support of top flange lead to an error of output of exploitation, because in this case it could be happened that the coefficient of buckling wasn't actualized.
This problem is cleared now.
permission Z-9.1-811 from 25. Mai 2010 added.


Version 01/10A


With Steico Joist could it occure that the significant combination for design of shear force wasn't found. This problem is cleared now.


Version 01/10


Steel

problems of communication with BTII eliminated.

Reinforced concrete

- run time of program is reduced
- at calculations of theory of plasticty the tension stiffness is considered now.
- at 2-axis strain the table for existing As is corrected.
- at 2-axis strain the reiforcement per corner is shown now in diagram of the resisting tensile force.
- at line of deflections fII(g) is shown additionally.
- colour of list of rods changed. Better visible now.

Timber

- at timbergirder with constant cross section in output of graphic was cross section no. 1 shown every time, although cross section no. 2 was selected. This problem is now eliminated.
- laminated veneer lumber as main material and as material for strengthening cross section of timber is selectable now (with DIN 1052:2008 and EN 5 only).
- in design window error corrected at 2-axis strain and multipart cross section
- DIN 1052 Italy added

General

- design specifications for actions of category H added.
it could be determined, if actions of category H are applied at the same time with other variable actions. Alternatively it could be determined if actions of category H are not applied at the same time with actions of snow or wind.
- design specifications added for alternative consideration of snowloads as accidental situation.
- at start of output the actual code is put out now.
- At output of gamma-times internal forces, the value of gamma-g is now put out too.
- term of cross section is put now in show of graphics.


Version 03/09


Timber

Correction: DIN 1052:2008 redistribution acc. 8.1.(6) is now considered.
Correction: DIN 1052:2004 At calculation of deflection could in any circumstances ocurre an error during calculation of variable initial deflection.

Steel

Adaption: for calculations with proof of torsional-flexural buckling the time of calculation had been otimized.

Reinforced concrete

Correction: reinforcement for ductility is no more considered for calculation of final anchorage, if it is generally deselected.
Correction: EN 1992-1: the coeficient for design of shear in connection with prefabricated units now is considered correctly.
Correction: EN 1992-1:function curtailed reinforcement of span is active now.

General

Symbols for internal forces are renewed at button bar.
New: minimal print output profile. Minimal print creates the smallest possible output without change of output format.
Correction : In any circumstances at transfer to column of reinforced concrete was the incorrect material delivered. This could cause that the column of concrete were calculated as steel column.
Dialogue design: advise row for req. Ac at 2-axis design of reinforced concrete has been corrected.
Dialogue material: minimum requirements of concrete quality by demands of durability were assumed.
Dialogue type of girder: changing the type of girder f.i. from wood to concrete will adapt the norms correctly.
Default setting at program start: Leaving the program saves type of girder, norm and 1- resp. 2-axis design automatically for next program start.


Version 02/09A


General

- Correction settlement: At calculation of nodal reactions the part out of the settlements was considered with the wrong sign.


Version 02/09


General

- After leaving the dialogue "settings of design" the graphic is updated now immediately.
- Earthquake: The action group of earthquake has been implemented. In the dialogue "settings of design" exists now the possibility to define special preferences for the design including loads of earthquake. Implementation of earthquake takes effect on the analysis of internal forces and the design. Structural adjustments in the reinforcement are not considered yet.
- Cross-section input: An input problem in the definition of cross-sections while changing between rectangle and plate beam was solved.

Aluminium

- In the input console "material" the name under the symbol "type of girder" has been corrected.

Steel

- For the design of steel girders an advanced calculation library has been implemented.
- In the output of deflections for biaxial systems the names of the direction y and z have been interchanged.

Timber

- Correction: The switch "All supports equal" is now considering the kc90 value.
- The design of vibration according to DIN 1052:2008 9.3 is considered in the design dialogue.
- In the dialogue of design the stress of the vibration design is now shown if the design of vibration is activated.
- The switch for the vibration design according to 9.3 is now placed in the register "material".
- Cross-section 1 of the system will now be displayed graphically.

Load forwarding

- The load forwarding to the reinforced concrete programs "Console Notched Bearing B10" and "Reinforced Concrete Corbel B9" is extended by geometric properties of the continuous beam.

Concrete

- The picture of reinforcement in the output is now saved with the position.
- ÖNORM B 4700: The deflection in the cracked condition was re-activated.
- Correction: Diagram of the existing tensile force at redistribution of moments.
- Correction: Design of crack width according to EN 1992-1-1.
- If in the concrete design output the tensile stress of steel or the compression stress in the concrete is not ok, the tensions are printed out bold now.
- Correction: Rotated reinforcement picture: The texts in the reinforcement will also be rotated now.
- Recess: Using recesses with plate beams the width of the cross-section at shear resistance is limited to the 3-times breadth of the web and 5-times height of the whole cross-section.
- Transfer from FEM: Optionally you can choose whether positions with many single loads the single loads shall be redistributed at 10 load points.
- EN 1992-1-1: Design of crack width: The authoritative exposure class is now being printed out.


Version 01/09B


Timber DIN 1052:1988

Correction for design with Program HO7.


Version 01/09A


STEICO BEAM:

- Adjustments in the calculation for the girder type STEICO.


Version 01/09


General

- Design Dialogue: The button "Apply" has been implemented. After the design of a collection of cross-sections the button "Apply" can be clicked. This means that the selected cross-section is displayed and the results for the selected cross-section are refreshed. This considers for example the point of design at vertical forces.

Timber

- For the design of timber girder a new design library was implemented.

Load forwarding

- The forwarding of loads to the reinforced concrete programs "Console Notched Bearing B10" and "Reinforced Concrete Corbel B9" has been implemented.
- The load forwarding from other programs has been extended to the load types 4, 5, 6, 14, 15, 16 supplements.

Concrete

- The setting for constant strut inclination at supports near the end of the girder possibly only worked with 45 degrees.
- Correction at the cutting of the diagram of vertical forces.
- Correction in the graphic according to circular recesses.
- Correction to the 2-axial design of vertical forces: The quantity of steel in the horizontal direction was possibly printed out to large by a factor of 100.


Version 04/08B


Ascii Interface

- Lintel without restraints may not be printed in the output.


Version 04/08A


ASCII interface

- Internal adjustments.


Version 04/08


General

- Options Menu: The different usage of partial safety factors by field for dead loads can now be defined by the chosen material. Note: DIN 1045-1 allows to use the partial safety factor of dead loads constant for the whole girder. This possibility is not extra allowed in the design standards for aluminium, steel and timber.
- Recess: Holes are now shown with measure dimension in the graphic. The geometric definition of the recess can be done according to the beginning of the hole or according to the middle of the hole.

Timber

- design of vertical forces: In addition to the existing options, to do the design of vertical forces with reduced single loads or with full single loads in the point of design near to the support, now it is also possible to work with reduced single loads considering the point of design directly at the support.
- Load forwarding: The load forwarding to the program "HO1 Timber Column" has been refreshed and extended to DIN 1052:2004.

Concrete

- The anchorage at the end of the beam is now available with 100% or 50% of the shear force in the axis of the ending support of girder.


Version 03/08


Correction

Interface adaptations in the context of cooperation with the company SEMA.


Version 02/08


Corrections

- Interface "Building GEO": Adjustments in cooperation with the "Building GEO" for action groups.
- DIN 1045-1: When using multiple cross-sections, it could happen that the wrong coefficients may be used at the design of incomplete interactions between joints.

General

- Options Menu: The immediate calculation after loading a position can now be disabled.
- Design of vertical forces: Horizontal jumps in cross-sections between support and point of design are considered now additionally.
-The load values gle /ple can now be accepted in the load values gri / pri by using the space bar.
- Graphic of loads: If more than 2 single loads are placed at the same position, 2 stars and a reference text are placed instead of the load value texts in the graphic.

Steel

- Design: If no cross-section is part of the defined area of design, the smallest cross-section of the current cross-section series is offered.

Reinforced concrete: DIN 1045-1

- Choice of design standards: DIN 1045-1 [2008] can be selected now.
- The reinforcement picture can be added to the output now.


Version 01/08B


Correction

Selection of design standard: Correction for the selection of reinforced concrete standard EC2 Italy.


Version 01/08A


Correction

- Correction load forwarding: When using freely-defined action groups in the forwarding load of the program "Building GEO" to the program "DLT Continuous Beam" it could be happen that the program shut down.


Version 01/08


Corrections

- DIN 1052: Using the enhanced profile it could happen that instead of the design value the characteristic value of tensile strength of steel was used for design.
- In uniaxial design and output of the minimal characteristic internal forces, the index "d" is removed from the table header.

General

Since this Version the shear deformation is optional switchable for each material.

Reinforced concrete: DIN 1045-1 [2001-07]

-The reduction of vertical forces at haunches according 10.3.2 is now optional be disabled.

Timber: DIN 1052 [2004-08]

- For the proof of support pressure the kc90-factor can be defined for each support separately now.
- Using the biaxial girder type the support pressure in the z-direction will be considered now.
- The simplified vibration design according to 9.3 can now be deactivated optionally.


Version 02/13_A


general

transfer of supportforces to STS is now possible.

zurück