S8 | Steel Chimney Design | Update Information


Version 01/16


Internal

Technical adjustment


Version 01/15


Internal

Technical adjustment


Version 01/12


Correction

Detail corrections


Version 01/11


Correction

The affected width of the bolts on the pipe jacket at the base plate is calculated with a maximum propagation angle of 45 degrees, if it is smaller than the affected width determined by the bolt distance.
(Additional information on the basis of calculation is given in the help text.)


Version 01/10


Correction

The calculation of the base/flange has been revised. The spring constants etc. are put out without partial safety factors. An iteration limit in the calculation of the base in accordance with Petersen has been corrected.


Version 01/08


Correction

Correction of the verification of the base service strength:
only half of the moment was applied to the base.