Collar Beam Roof
DKD+
Calculation of collar beam roofs with sway or non-sway collar beams. The collar beam can consist of one or two parts.
Discover now more programs from the section Roof!
SHOW MOREMaterial
- Softwood
- Hardwood
- Glulam
Structural system
- Both sides of the roof consist of straight continuous rafters having an inclination and the same cross-section over several spans without intermediate joints
- The roof pitch, the cross-sections and the span lengths can differ on the left and right side
- Different rafter spacing on the left and right side
- The cantilevers can have a different cross-section
- The projection over the ground plan of the house can deviate from the cantilever geometry
- The supports are sway in the horizontal and vertical direction or are restrained. The restraints can be defined as being rigid or elastic
- A collar beam with up to four spans can be defined
Loads
- Automatic generation of the loads from self-weight, snow, and wind
- Additional user-defined loads as uniformly distributed loads, concentrated loads or trapezoidal loads
- Man loads as well as wind uplift at projections
- Accidental snow load is optionally available
- Loads from photovoltaic arrays
- To reduce the computing time for more extensive systems, various settings are available for the grouping of load cases and load combinations
Design settings
Optionally selectable:
- Verification of the wind suction resistance
- Seismic load combinations
- Hot design
- As a standard option, only positive deflections are verified on the cantilever (on short cantilevers, the negative deflection is often decisive in terms of calculation, but this is not always desired)
Effective length for buckling and lateral buckling separately for the cold and hot design:
- Default setting: calculation of the effective length for buckling from the eigenvalue solution of the plane system. Assumption of continuous lateral support with limitation of the maximum effective length for buckling in the rafter plane to 0.9 times the component length
- Alternatively, setting the effective length to the length of the member, the component or a default value
Connection details
Base
- Connection with a notch or pole plate
- Connection with a straight or haunched cleat
Purlin support
- With birdsmouth joint
- With nailed cleat
Document file formats
- Word
- Printer
Output
- User-defined output with various setting options for tables and graphics
- Result graphics with internal forces, stresses, or displacements can be specifically transferred to the output document using the camera button
- Support reactions are optionally put out for each load case, each action or as min/max values, either for each rafter or per linear metre
Transfer options
- System transfer to the other Roof programs
- System transfer to the RSX Frame program
- Transfer of support reactions to the Continuous Timber Beam program HTM+
- Transfer of support reactions to the Continuous Steel Beam program STM+
- Transfer of support reactions to the Timber Column program HO1+
- Direct interface to the CAD programs from SEMA
Timber construction
- DIN EN 1995
- ÖNORM EN 1995
- NTC EN 1995
- BS EN 1995
- PN EN 1995
- EN 1995
Support resources
News

Release 2023-2: FRILO presents a new program for the calculation of strut-and-tie models in reinforced concrete construction
FRILO Software GmbH has successfully delivered the software version 2023-2. With the update, the provider of innovative solutions for structural analysis and design is launching a new program that allows the generation of frameworks in reinforced concrete construction.

BAU 2023 a complete success for FRILO, SCIA and DC
At the joint stand of the Nemetschek Group, FRILO, SCIA and DC presented the software range for structural analysis and foundation engineering.
Events

06.06.23
10:00 AM - 11:00 AM CET