Infiltration Installation
The “Infiltration Installation” program can be used to analyze infiltration installations. Different types of infiltration and infiltration installations are available and a distinction can be made between infiltration of precipitation or a specified inflow volume, e. g. from dewatering of a construction site. Rainfall intensities and precipitation depths can be imported from the KOSTRA Atlas or eHYD and MeteoSwiss. In addition, it can be checked whether rainwater treatment in accordance with Code of Practice DWA-M 153 of the German Association for Water, Wastewater and Waste should be taken into account.
Only available in FRILO Geotechnic Ultimate
Performance characteristics
Structural system
- Selectable types of infiltration:
- area infiltration
- trough infiltration
- drain-trench infiltration
- trough drain-trench infiltration
- canal drain-trench infiltration
- block drain-trench infiltration
- trough canal drain-trench infiltration
- well infiltration type A/B according to ADTV and Herth-Arndt
- infiltration basin and horizontal drains
- Free definition of the rainfall intensity
Geotechnical verifications
- Analysis of infiltration installations according to DWA-A 138, ÖNORM B 2506-1 and Herth-Arndts
- Analysis of the infiltration optionally with precipitation with the corresponding rainfall intensities or with a specified inflow volume, e. g. from dewatering of a construction site
- Analysis of the infiltration for horizontal drains depending on the parameters of the drainpipes
- Analysis of the well infiltration optionally with the dam-up height and the extent or the required well diameter or well number with a specified inflow and a permissible dam-up height
- Partial area analysis with run-off coefficients
Verification of rainwater treatment
- Verification of wether rainwater treatment is required in accordance with the Code of Practice with D < D,max
- Selection of the loading from air and area for the areas to be drained and the type of water body
- Selection of the passage values for the treatment according to the tables of the DWA-M 153 Code of Practice
Results
- Display of the table representing the rainfall intensities for different durations and the decisive value with selectable scope
- Automatic optimisation of drain trench lengths and trough areas
File format
- Printer
Import options
- Import of rainfall intensities from the KOSTRA Atlas
- Import of precipitation depths from eHYD (Austria) and MeteoSchweiz (Switzerland) with automatic conversion into rainfall intensities
Export options
- RTF export to MS Word
- Graphic export in JPG format
- DXF export
Foundation engineering
- EN 1997-1
- DIN EN 1997-1
- DIN 1054
- DIN 4126
Support resources
News

FRILO launches version 2024-2 with powerful updates for structural analysis and design
Highlights include the optimised design of Schöck Isokörbe®, the advanced integration of DC foundation engineering programs into the FRILO environment and new RSX interfaces for detail verifications in steel construction.

Load determination for eight-floor perimeter block development with FRILO Building Model
Find out how the structural engineers at bauart Konstruktions GmbH determined the loads for an eight-floor perimeter block development in Frankfurt’s Europaviertel district using the GEO from FRILO.