Steel Connection
The “Steel Connection” module can be used to analyze and design steel connections such as butt plate joints, fin plates, welded and bolted frame corners, splice connections, steel angle connections, and typified steel connections.
Only available in FRILO Ultimate
Performance characteristics
With the feature, fin plate connections in steel construction can be analyzed and designed. The program performs all required verifications for fin plate connections in the configurations “secondary beam to steel beam” or “secondary beam to steel column”.
Material
The material can be selected differently for the main beam, secondary beam, support and fin plate.
- Structural steel: S235, S275, S355, S450
- Annealed steel (S275N to S460N)
- Thermo-steel (S275M to S460M)
- Weathering steel (S235W to S355W)
- High-temperature steel (S460Q to S460QL1)
- Hollow section, hot-finished (S235H to S355H)
- Hollow section, hot-finished, fine-grain (S275NH to S460NH)
- User-defined steel
Structural system
Available systems:
- Fin plate connection: secondary beam to steel beam
- Fin plate connection: secondary beam to steel column
- Flexurally rigid connection at weld seam or at bolt centre of gravity
- For a connection to a beam, the secondary beam can have a notch on top, on bottom, or on both sides
Cross-sections:
- I-sections as standard shapes
- User-defined I-sections
Loads
- Depending on the selected design model (flexurally rigid at the weld seam or in the bolt pattern), design internal forces caused by axial force, moment, and shear force can be defined.
- Design internal forces refer to the centre of gravity of the bolt pattern.
- Multiple combinations of design internal forces can be entered.
Fasteners
- Bolts (black bolts and fit bolts)
- Sizes: M12; M16; M20; M22; M24; M27; M30; M36
- Strength classes: 4.6; 5.6; 8.8; 10.9
Design
Either the elastic or plastic cross-sectional resistance of the fin plate is verified. For the verification of the weld seam, the user can select whether the simplified or directional method should be used. For the bolted connection, the verification of the embedding pressure as well as the verification of shear action are performed.
Results
- Pre-defined standard scope
- Brief scope
- Extensive scope
File formats
- Word
- Printer
Import options
- ASCII
Export options
- Word
- ASCII
Steel construction
- DIN EN 1993
- Ă–NORM EN 1993
- BS EN 1993
Support resources
News

FRILO launches version 2024-2 with powerful updates for structural analysis and design
Highlights include the optimised design of Schöck Isokörbe®, the advanced integration of DC foundation engineering programs into the FRILO environment and new RSX interfaces for detail verifications in steel construction.

Load determination for eight-floor perimeter block development with FRILO Building Model
Find out how the structural engineers at bauart Konstruktions GmbH determined the loads for an eight-floor perimeter block development in Frankfurt’s Europaviertel district using the GEO from FRILO.