FRILO PRODUCTS

Solutions for everyday verifications

FRILO’s toolboxes are a hodgepodge of different verification modules that all have one thing in common: They handle regularly recurring, small standard calculations that are part of the daily work in an engineering office. With regard to the subject, the toolboxes can be divided into the sections reinforced concrete, fire protection in reinforced concrete, timber construction and masonry. The little helpers primarily perform common detail verifications. It is best to get an overview yourself.

Find the perfect product for you.

Filter
Search for
Material
Verification
Component

Bearing Pressure

Verify the load capacity of the bearing pressure depending on the load position and the selected masonry

LEARN MORE

Collar Beam Connection with Cleat

Carry out a verification for one-part collar beam connections with a cleat in accordance with EC 5

LEARN MORE

Collar Beam Connection with Connector Joints

Carry out a verification for two-part collar beam connections with special design anchors in accordance with EC 5

LEARN MORE

Collar Beam Connection with Nails

Carry out a verification for two-part nailed collar beam connections in accordance with EC 5

LEARN MORE

Column Load Transfer

Verify the transmission of column loads through reinforced concrete floors in normal concrete

LEARN MORE

Cross-Sectional Properties

Calculate cross-section values for a number of standard cross-sections

LEARN MORE

Deep Beam

Carry out a verification for a wall-type single-span beam made of normal concrete

LEARN MORE

Deformation without Check

Carry out a simplified verification for the limitation of deformation according to EC 2

LEARN MORE

Fire Protection Beam

Identify minimum distances for reinforced concrete beams under three- or four-sided fire exposure

LEARN MORE

Fire Protection Ribbed Slab

Identify minimum distances for ribbed slabs made of reinforced and prestressed concrete in case of fire from below

LEARN MORE

Fire Protection Slab

Identify minimum distances for uniaxially and biaxially tensioned floor slabs under fire exposure

LEARN MORE

Fire Protection Wall and Column

Identify duration of fire exposure for reinforced concrete walls and columns at minimum distances

LEARN MORE

Frame Corner with Positive Moment

Carry out a verification for lap and anchorage lengths of the specified reinforcement for frame corners

LEARN MORE

Half Joint Slab

Carry out a verification for notched slab supports

LEARN MORE

Horizontal Beam Interface

Carry out a verification for composite joint for reinforced concrete beams

LEARN MORE

Indirect Support

Carry out a verification for the indirect support of a beam

LEARN MORE

Infill Masonry

Carry out a simplified verification for predominantly wind-loaded, non-load-bearing infill walls

LEARN MORE

Line Corbel Beam

Carry out a verification for line corbels on a beam

LEARN MORE

Line Corbel Slab

Carry out a verification for line brackets on a ceiling edge

LEARN MORE

Line Corbel Wall

Carry out a verification for line brackets on a wall

LEARN MORE

Non-bearing Inner Partition

Carry out a verification for vertically non-stressed interior walls with limited horizontal loading

LEARN MORE

Notch Stairs Bottom

Carry out a verification for stair supports that are notched at the bottom

LEARN MORE

Notch Stairs Top

Carry out a verification for stair supports that are notched at the top

LEARN MORE

Partial Loaded Area

Carry out a verification of partial area loads in accordance with DIN EN 1992-1-1

LEARN MORE

Purlin Support with Cleat

Carry out a verification for purlin connections with a nailed-on cleat in accordance with EC 5

LEARN MORE

Rafter Base Point

Verify base points of rafters with transverse and normal forces (e.g. of rafter or collar beam roofs)

LEARN MORE

Rafter Base Point with Cleat

Verify rafter foot points with cleats with transverse and normal forces

LEARN MORE

Rafter Base Point with Haunched Cleat

Verify rafter base points with haunched cleats with transverse and normal forces

LEARN MORE

Rafter Support

Verify the bearing pressure of a rafter depending on load positions, geometry and material

LEARN MORE

Shear Dowel

Carry out a verification for shear dowels made of reinforcing steel

LEARN MORE

Sleeper Anchoring

Carry out a verification for sleeper anchors with washer in accordance with EC 5

LEARN MORE

Splitting Force

Carry out a verification for splitting and edge tensile forces

LEARN MORE

Threaded Rod

Carry out a verification for concreted-in shear dowels made of threaded rods

LEARN MORE

Timber Compression

Verify timber compression perpendicular to the grain depending on the load positions, geometry and material

LEARN MORE

Timber Compression Steel Plate

Verify timber compressions with the aid of a steel plate for load distribution perpendicula to the grain

LEARN MORE

Unreinforced Concrete Wall

carry out all necessary verifications for unreinforced concrete walls in accordance with EC 2

LEARN MORE

Volume Calculation

Carry out a volume calculation for a whole series of objects

LEARN MORE

Würth Tafelanker

Carry out a verification for Würth panel anchors according to approval

LEARN MORE

Thank you for your enquiry!

You have successfully applied for a student license for the chosen software. As we still need to check the information you have provided, including your enrollment certificate, the license will not be made available to you immediately. We therefore ask for your patience while we verify your submission. We will endeavor to process your application as quickly as possible.